4-4 DL3100 User’s Guide—November 1998
4
1. Using a cable with DE-9 connectors, connect the cableÕs DE-9
socket connector to the terminal (or modem if at a remote site).
Ribbon-type cables can be ordered from Digital Link by the
following part numbers:
2. Connect the cableÕs DE-9 plug connector to the TERMINAL port
socket on each DL3100 (Figure 4-1).
Change the TERMINAL port setting to Multidrop Mode on all units.
3. To multidrop the NETWORK MANAGEMENT port, connect the
cableÕs DE-9 plug connector to the NETWORK MANAGEMENT
port socket on each DL3100. Plug the socket end of the DE-9 cable
to your NMS workstation.
The connection between your DL3100 and your NMS workstation
must be a SLIP connection.
For detailed instructions on installing SNMP systems, refer to the separate
installation guides for these products.
Table 4-1 Part Numbers for DL3100 Units
To daisy chain: Order Part No.
Four units 154-00051-01
Eight units 154-00052-01
Twelve units 154-00053-01
NOTE: When units are daisy-chained together, the units must be
operating in Multidrop Mode. For more information about Multidrop
Mode, see “Configuring the DL3100” on page 4-10. Each unit should
be given a unique node number.