4-1
4
Maintenance 4
This chapter discusses maintenance methods for the Solo E1 DSU:
¥ ÒMenu-1 Main StatusÓ on page 4-2
¥ ÒMenu-2 Data StatusÓ on page 4-5
¥ ÒCheck EfÞciency with Menu-3 Performance ReportsÓ on page 4-6
¥ ÒEvent LogÓ on page 4-12
The Solo E1 DSU collects and displays performance data to help you
manage and troubleshoot problems on the network. It monitors the line
continuously and displays the data on a terminal screen.
You can monitor and manage the Solo E1 DSU:
¥ From an ANSI terminal
¥ A Telnet connection
¥ An SNMP network management station (NMS) connected to the
COMM port.
The front panel LEDs also show the Solo E1 DSU status (refer to ÒInstalling
the ModuleÓ on page 2-18).
Monitor the status of the Solo E1 DSU from Menu-1 Main Status and the
status of the single DATA port from Menu-2 Data DTE Status.
Use the menus to troubleshoot the Solo E1 DSU:
¥ Menu-1 Main StatusÑdisplays Solo E1 DSU status
¥ Menu-3 Performance ReportsÑdisplays carrier and user registers, and
the event log.
¥ Menu-9 DiagnosticsÑto verify connections and circuits and
troubleshoot problems (refer to Figure 5-1 on page 5-2).
How Alarms Are Reported and Displayed
The Solo E1 DSU always reports all alarm conditions to either:
¥ The device connected to its COMM port (such as a terminal, printer, or
modem).
¥ The device connected to the COMM port of the remote device if
Connection is set to IBC (in Menu-8 Alarm II) on the local device.